Rooftop mounted systems are small compared to ground-mounted photovoltaic power stations with capacities in the megawatt range. Rooftop PV systems on residential buildings typically feature a capacity of about 5 to 20 kilowatts (kW), while those mounted on commercial buildings often reach 100 kilowatts or more.
Installation
The urban environment provides a large amount of empty rooftop spaces and can inherently avoid the potential land use and environmental concerns. Estimating rooftop solar insolation is a multi-faceted process, as insolation values in rooftops are impacted by the following:
Time of the year
Latitude
Weather conditions
Roof slope
Roof aspect
Shading from adjacent buildings and vegetation
There are various methods for calculating potential solar PV roof systems including the use of Lidar and orthophotos. Sophisticated models can even determine shading losses over large areas for PV deployment at the municipal level.
Feed-in tariff mechanism
In a grid connected rooftop photovoltaic power station, the generated electricity can sometimes be sold to the servicing electric utility for use elsewhere in the grid. This arrangement provides payback for the investment of the installer. Many consumers from across the world are switching to this mechanism owing to the revenue yielded. A public utility commission usually sets the rate that the utility pays for this electricity, which could be at the retail rate or the lower wholesale rate, greatly affecting solar power payback and installation demand.
The FIT as it is commonly known has led to an expansion in the solar PV industry worldwide. Thousands of jobs have been created through this form of subsidy. However it can produce a bubble effect which can burst when the FIT is removed. It has also increased the ability for localised production and embedded generation reducing transmission losses through power lines.
Hybrid systems
A rooftop photovoltaic power station (either on-grid or off-grid) can be used in conjunction with other power components like diesel generators, wind turbines, batteries etc. These solar hybrid power systems may be capable of providing a continuous source of power.
Advantages
Installers have the right to feed solar electricity into the public grid and hence receive a reasonable premium tariff per generated kWh reflecting the benefits of solar electricity to compensate for the current extra costs of PV electricity.
Disadvantages
An electrical power system containing a 10% contribution from PV stations would require a 2.5% increase in load frequency control (LFC) capacity over a conventional system[jargon] - in issue which may be countered by using synchronverters in the DC/AC-circuit of the PV system. The break-even cost for PV power generation was in 1996 found to be relatively high for contribution levels of less than 10%. Higher proportions of PV power generation gives lower break-even costs, but economic and LFC considerations imposed an upper limit of about 10% on PV contributions to the overall power systems.
Technical Challenges
There are many technical challenges to integrating large amounts of rooftop PV systems to the power grid. For example:
Reverse Power Flow
The electric power grid was not designed for two way power flow at the distribution level. Distribution feeders are usually designed as a radial system for one way power flow transmitted over long distances from large centralized generators to customer loads at the end of the distribution feeder. Now with localized and distributed solar PV generation on rooftops, reverse flow causes power to flow to the substation and transformer, causing significant challenges. This has adverse effects on protection coordination and voltage regulators.
Ramp rates
Rapid fluctuations of generation from PV systems due to intermittent clouds cause undesirable levels of voltage variability in the distribution feeder. At high penetration of rooftop PV, this voltage variability reduces the stability of the grid due to transient imbalance in load and generation and causes voltage and frequency to exceed set limits if not countered by power controls. That is, the centralized generators cannot ramp fast enough to match the variability of the PV systems causing frequency mismatch in the nearby system. This could lead to blackouts. This is an example of how a simple localized rooftop PV system can affect the larger power grid. The issue is partially mitigated by distributing solar panels over a wide area, and by adding storage.
Cost
Residential PV system prices (2013)
Country | Cost ($/W) |
---|---|
Australia | 1.8 |
China | 1.5 |
France | 4.1 |
Germany | 2.4 |
Italy | 2.8 |
Japan | 4.2 |
United Kingdom | 2.8 |
United States | 4.9 |
For residential PV systems in 2013 |
Commercial PV system prices (2013)
Country | Cost ($/W) |
---|---|
Australia | 1.7 |
China | 1.4 |
France | 2.7 |
Germany | 1.8 |
Italy | 1.9 |
Japan | 3.6 |
United Kingdom | 2.4 |
United States | 4.5 |
For commercial PV systems in 2013 |
In the mid-2000s, solar companies used various financing plans for customers such as leases and power purchase agreements. Customers could pay for their solar panels over a span of years, and get help with payments from credits from net metering programs. As of May 2017, installation of a rooftop solar system costs an average of $20,000. In the past, it was more expensive.
Utility Dive wrote, "For most people, adding a solar system on top of other bills and priorities is a luxury" and "rooftop solar companies by and large cater to the wealthier portions of the American population."
Most households that get solar arrays are "upper middle-income". The average household salary for solar customers is around $100,000.
However, "a surprising amount of low-income" customers appeared in a study of income and solar system purchases. "Based on the findings of the study, GTM researchers estimate that the four solar markets include more than 100,000 installations at low-income properties."
A report released in June 2018 by the Consumer Energy Alliance (CEA) that analyzed U.S. solar incentives showed that a combination of federal, state and local incentives, along with the declining net cost of installing PV systems, has caused a greater usage of rooftop solar across the nation. According to Daily Energy Insider, "In 2016, residential solar PV capacity grew 20 percent over the prior year, the report said. The average installed cost of residential solar, meanwhile, dropped 21 percent to $2.84 per watt-dc in the first quarter of 2017 versus first quarter 2015." In fact, in eight states the group studied, the total government incentives for installing a rooftop solar PV system actually exceeded the cost of doing so.
Future prospects
The Jawaharlal Nehru National Solar Mission of the Indian government is planning to install utility scale grid-connected solar photovoltaic systems including rooftop photovoltaic systems with the combined capacity of up to 100 gigawatts by 2022.